Boneco
Fan Motor Failure (Dehumidifier)
Dehumidifier fan does not run but compressor is trying to start
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Burned-out fan motor, Seized fan bearings, Failed fan capacitor (if used), Broken fan motor wiring
How to Fix / Troubleshooting
Safety: Unplug the unit before accessing internal components.
Steps:
- Check for obstructions: Ensure nothing is blocking the fan blades.
- Spin test: Try spinning the fan by hand (with power off). If it is stiff or seized, the motor bearings are likely failed.
- Inspect wiring: Check the fan motor wires and connector at the main PCB for damage or looseness.
- Capacitor check: Some fan motors use a run capacitor. Inspect for bulging or leakage. Replace with the same capacitance and voltage rating if defective.
- Replace fan motor: If the motor is open-circuit or seized, replace the dehumidifier fan motor assembly. Transfer the fan blade to the new motor and secure it properly.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Dehumidifier Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.