FILL
Boneco
Empty Tank / Low Water Condition
Display shows 'FILL' or water droplet icon flashes and unit stops producing mist
Advertisements
Possible Causes
Water tank empty or not fully seated, Stuck float in low position, Faulty water level sensor, Blocked tank valve preventing water from entering base
How to Fix / Troubleshooting
Safety: Turn off and unplug before removing the tank.
Steps:
- Refill the tank: Remove the tank, open the cap, and fill with clean, preferably demineralized water. Tighten the cap securely.
- Check tank valve: Inspect the spring-loaded valve in the tank cap. Press it gently to ensure it moves freely and is not stuck closed.
- Reinstall the tank: Place the tank back on the base, ensuring it is aligned and fully seated. You should see air bubbles rising as water flows into the base.
- Inspect float and sensor: If 'FILL' remains, remove the tank and check the float in the base for free movement. Clean any scale or debris.
- Test again: After cleaning and refilling, restart the unit. If the error persists with a full tank, the water level sensor or float switch may be defective and require replacement.
Advertisements
Repair Difficulty
Very Easy
1/5
Required Part
Water Level Float Switch Assembly
Check Price on Amazon