Possible Causes
Loose fan blade or mounting screws, Worn fan motor bearings, Compressor mounting grommets deteriorated, Cabinet panels vibrating
How to Fix / Troubleshooting
Safety: Unplug the Camry unit before tightening or adjusting any components.
Steps:
- 1. Check placement: Ensure the unit is on a level, solid surface. Avoid hollow floors or unstable stands.
- 2. Inspect fan assembly: Remove the grille and check that the fan blade is firmly attached to the motor shaft. Tighten the set screw if present.
- 3. Tighten screws: Check all visible cabinet and frame screws. Tighten any that are loose.
- 4. Inspect motor bearings: If the noise is a grinding or squealing from the fan area, the fan motor bearings may be worn. Replace the fan motor if lubrication does not help (most are sealed and non-serviceable).
- 5. Compressor mounts: Inspect the rubber compressor mounting grommets. If cracked or missing, replace with new compressor mounting grommets to reduce vibration.
Tip: Adding thin foam pads under the unit’s feet can further reduce transmitted vibration.