E6
Camry
Communication Error Between Display PCB and Main Control PCB
Dehumidifier shows E6 and stops operation, sometimes after a power surge
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose communication harness between display and main board, Damaged ribbon cable, Faulty display PCB, Faulty main control PCB
How to Fix / Troubleshooting
Safety: Disconnect the Camry dehumidifier from mains power before opening the cabinet.
Steps:
- 1. Power cycle: Unplug for 10 minutes, then reconnect. If E6 returns, proceed.
- 2. Access control area: Remove the top or front cover to expose the control panel and main PCB.
- 3. Inspect communication cable: Locate the multi-wire harness or flat ribbon cable running from the display PCB to the main control PCB. Check for pinched, cut, or burnt sections.
- 4. Reseat connectors: Disconnect the harness at both ends, inspect for bent pins or corrosion, then firmly reconnect. Ensure the connector latches are fully engaged.
- 5. Visual inspection of PCBs: Look for burn marks, swollen components, or cracked solder joints on both boards.
- 6. Replace suspect board: If wiring is intact and E6 persists, replace the display PCB first (often easier and cheaper). If that does not resolve the issue, the main control PCB may need replacement.
Note: Always order Camry-specific control boards using the full model and serial number to ensure compatibility.