F1
Camry
Humidifier Water Level Sensor Fault
Humidifier function disabled, F1 shown on display (on combo humidifier/dehumidifier models)
Advertisements
Possible Causes
Empty water tank, Stuck float in humidifier reservoir, Faulty humidifier level sensor, Loose sensor wiring to control PCB
How to Fix / Troubleshooting
Safety: Unplug the Camry humidifier/dehumidifier combo before servicing the water system.
Steps:
- 1. Check water level: Remove the humidifier tank or reservoir and fill it to the indicated level with clean water. Reinstall securely.
- 2. Inspect float: Locate the float inside the humidifier reservoir. Ensure it moves freely and is not coated with scale or slime. Clean with a soft brush and mild detergent, then rinse.
- 3. Test level sensor: Access the internal humidifier water level sensor or float switch. Manually move the float and listen for a click or use a multimeter to verify continuity changes.
- 4. Check wiring: Follow the sensor wires to the control PCB. Reseat the connector and inspect for damage.
- 5. Replace sensor: If the switch or sensor does not operate electrically, replace it with the correct Camry humidifier level sensor for your model.
Tip: Use filtered or low-mineral water to reduce scale buildup on floats and sensors.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Humidifier Water Level Sensor
Check Price on Amazon