F3
Camry
Humidifier Ultrasonic Transducer / Heater Drive Fault
Humidifier mode error F3, fan may run but no mist output
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed ultrasonic transducer disc, Burnt driver circuit on humidifier PCB, Loose wiring to humidifier module
How to Fix / Troubleshooting
Safety: Unplug the Camry unit before opening the humidifier section.
Steps:
- 1. Check water and scale: Remove the humidifier tank and inspect the ultrasonic transducer or heater chamber for heavy scale. Clean gently with white vinegar and a soft cloth, then rinse thoroughly.
- 2. Inspect transducer: Look for cracks or discoloration on the ultrasonic disc. A visibly damaged disc must be replaced.
- 3. Check wiring: Ensure the wires from the main PCB to the humidifier module are firmly connected and not corroded.
- 4. Replace module: If F3 persists and the disc appears damaged or the driver board shows burn marks, replace the complete Camry ultrasonic humidifier module or heater assembly, depending on model.
Note: Always use the correct replacement module specified for your Camry model to ensure proper drive frequency and safety.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Ultrasonic Humidifier Module
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements