P1
Camry Defrost / Preheating Mode Active

Dehumidifier shows P1 and does not start dehumidifying

Advertisements

Possible Causes

Low room temperature causing frequent defrost, Evaporator sensor detecting frost, Control logic holding unit in defrost

How to Fix / Troubleshooting

Safety: No internal repair is usually required for P1; it is often a status code. Always unplug before opening the unit if you choose to inspect.

Steps:

  • 1. Check ambient temperature: Ensure the room is within the operating range (typically above 5–10°C). Move the unit to a warmer room if necessary.
  • 2. Allow defrost cycle: Leave the unit plugged in and powered on. P1 may clear automatically after the defrost cycle completes.
  • 3. Clean filters and coils: Restricted airflow can cause excessive frosting. Clean the air filter and evaporator coil as described in other entries.
  • 4. Sensor check: If P1 never clears, inspect the evaporator/defrost sensor for proper attachment and operation as in the E2/E9 procedures.

Note: If the unit remains stuck in P1 despite normal temperature and clean coils, the control PCB or sensor may be faulty.

Advertisements

Repair Difficulty

Easy 2/5