Camry
Keypad / Touch Control Failure
Humidifier or dehumidifier buttons do not respond or respond intermittently
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Worn membrane keypad, Moisture ingress into control panel, Loose ribbon cable to display PCB, Faulty touch sensor IC
How to Fix / Troubleshooting
Safety: Unplug the unit before opening the control panel.
Steps:
- 1. Dry the panel: If the panel was exposed to moisture, allow it to dry completely in a warm, dry room.
- 2. Clean surface: Wipe the keypad area with a soft, dry cloth. Do not use excessive liquid cleaners.
- 3. Inspect ribbon cable: Remove the control panel cover and check the ribbon cable between the keypad and display PCB. Reseat both ends.
- 4. Test buttons: With the panel open (and power reconnected carefully if necessary), test button response. If some buttons never work, the keypad membrane is likely faulty.
- 5. Replace keypad or display PCB: Install a new Camry control panel keypad or complete display PCB assembly as required.
Warning: Take care to avoid contact with live circuits if testing with power applied. If unsure, disconnect power and perform only visual checks.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Control Panel Keypad
Check Price on Amazon
We may earn a commission from links on this page.