Camry
Low Humidification Output
Humidifier runs but produces very little or no mist
Advertisements
Possible Causes
Scaled ultrasonic transducer, Clogged mist outlet, Low water level, Failed ultrasonic driver circuit
How to Fix / Troubleshooting
Safety: Unplug the Camry humidifier before cleaning. Do not immerse electrical parts in water.
Steps:
- 1. Check water level: Ensure the tank is full and properly seated.
- 2. Descale transducer: Remove the tank and expose the ultrasonic transducer. Soak the transducer area with white vinegar for 10–15 minutes, then gently scrub with a soft brush. Rinse thoroughly.
- 3. Clean mist outlet: Inspect the mist outlet and channels for dust or mineral buildup. Clean with a cotton swab and mild detergent.
- 4. Test output: Reassemble, refill, and run the unit. If there is still no mist and you hear no high-frequency buzzing from the transducer, the ultrasonic driver PCB or module may be faulty.
- 5. Replace module: Install a new Camry ultrasonic humidifier module if required.
Tip: Use distilled or low-mineral water to reduce scale buildup and extend transducer life.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Ultrasonic Humidifier Module