Carrier
Mechanical Vibration or Fan/Compressor Noise
Dehumidifier is very noisy during operation; rattling, buzzing, or grinding sounds.
Advertisements
Possible Causes
Loose fan blade, Worn fan motor bearings, Loose compressor mounting grommets, Cabinet panels vibrating against frame
How to Fix / Troubleshooting
Safety first: Unplug the unit before touching internal parts. Keep fingers clear of fan blades.
Steps:
- 1. Level the unit: Ensure the dehumidifier is on a flat, solid surface. Use shims if necessary.
- 2. Inspect fan assembly: Remove the cover and check that the fan blade is tight on the motor shaft and not contacting the shroud. Tighten or reposition as needed.
- 3. Check motor bearings: Spin the fan by hand. If you hear grinding or feel roughness, the motor bearings are worn and the motor should be replaced.
- 4. Compressor mounts: Inspect the rubber grommets under the compressor. If they are cracked or missing, vibration will transfer to the cabinet. Replace grommets if accessible.
- 5. Tighten panels: Tighten any loose screws on the cabinet and add foam tape between vibrating metal surfaces if needed.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Fan Motor Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements