Carrier Compressor Overheating / Thermal Overload Trip

Dehumidifier runs briefly then shuts off; may restart after several minutes.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dirty condenser coil, Failed condenser fan motor, Low or high refrigerant charge, Failing compressor drawing high current

How to Fix / Troubleshooting

Safety first: Unplug the unit and allow it to cool before touching the compressor area.

Steps:

  • 1. Clean coils and filter: Ensure the condenser coil and air filter are clean to promote proper cooling.
  • 2. Verify fan operation: Confirm that the fan runs whenever the compressor is on. Replace the fan motor if it stops or runs slowly.
  • 3. Check room temperature: Extremely high ambient temperatures can cause overheating. Improve ventilation around the unit.

Next steps: If the compressor continues to overheat and trip, a technician should check refrigerant charge and compressor health.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Condenser Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.