E5
Carrier Refrigerant System or High-Pressure Protection Fault

Dehumidifier shows E5 and the compressor does not start or shuts off quickly after starting.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked condenser coil, Failed condenser fan motor, Overcharged or undercharged refrigerant system, Faulty high-pressure switch (if equipped)

How to Fix / Troubleshooting

Safety first: Unplug the unit. Do not attempt to open the sealed refrigeration system yourself; refrigerant work must be done by an EPA-certified technician.

Steps a homeowner can take:

  • 1. Clean air filters and coils: Remove and wash the air filter. Use a soft brush and vacuum to clean dust from the condenser (warm) coil. Restricted airflow can cause high pressure and trigger E5.
  • 2. Check condenser fan operation: Plug the unit back in and observe (from a safe distance) whether the fan runs when the compressor attempts to start. If the fan does not run, the compressor may overheat and shut down.
  • 3. Inspect fan area: With power disconnected again, check for obstructions (plastic bags, insulation, debris) blocking the fan blade. Spin the blade by hand; it should turn freely without grinding.
  • 4. Test/replace fan motor: If the blade is free but the motor does not run when powered, the condenser fan motor is likely failed and should be replaced with the correct Carrier motor assembly.
  • 5. Evaluate environment: Ensure the unit has at least 12 inches of clearance around it and is not operating in a confined, overheated space.

When to call a technician: If the fan and airflow are normal but E5 persists, the issue may be refrigerant charge, a blocked capillary/expansion device, or a faulty high-pressure switch. These require a Carrier-qualified refrigeration technician.