F0
Carrier Low Ambient Temperature / Frost Protection Lockout

Dehumidifier shows F0 and will not start or runs only briefly.

Advertisements

Possible Causes

Room temperature below operating range, Faulty ambient temperature sensor, Control board misinterpreting temperature

How to Fix / Troubleshooting

Safety first: Unplug the unit before moving it.

Steps:

  • 1. Check room temperature: Many Carrier dehumidifiers are designed to operate above about 41–50°F (5–10°C). If the space is colder, the unit may show F0 and lock out to prevent coil icing.
  • 2. Move to warmer area: If possible, relocate the unit to a warmer room and allow it to acclimate for 1–2 hours before restarting.
  • 3. Inspect ambient sensor: If F0 appears even in a warm room, inspect and test the ambient thermistor as described under E2. Replace if out of specification.
  • 4. Control board check: If the sensor is good, the main control board may be misreading temperature and require replacement.

Note: F0 is often informational; no repair is needed if the unit is simply being used in too cold an environment.