F1
Carrier
Humidity Sensor Calibration / Fault Error
Dehumidifier displays F1 and does not respond correctly to humidity settings.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Out-of-calibration humidity sensor, Sensor contamination from dust or chemicals, Failed humidity sensor module, Control board RH input fault
How to Fix / Troubleshooting
Safety first: Unplug the unit before accessing the control area.
Steps:
- 1. Compare humidity readings: Place a reliable hygrometer near the dehumidifier intake. If the unit’s display differs by more than 10–15% RH, the sensor may be out of calibration.
- 2. Clean sensor area: Gently blow dry compressed air across the humidity sensor to remove dust. Do not touch the sensor element with fingers or liquids.
- 3. Reseat connector: Disconnect and reconnect the humidity sensor harness at the main board.
- 4. Replace sensor: If F1 persists or readings remain inaccurate, replace the humidity sensor with the correct Carrier part.
- 5. Control board replacement: If a new sensor does not resolve F1, the main control board may be defective and should be replaced.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Humidity Sensor
Check Price on Amazon
We may earn a commission from links on this page.