H3
Carrier Humidistat / Humidity Control Fault

Carrier thermostat or humidifier control shows H3; humidifier runs continuously or not at all regardless of humidity setting.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed built-in humidistat in Carrier control, Miswired external humidistat, Shorted or open humidistat wiring, Control board logic failure

How to Fix / Troubleshooting

Safety first: Turn off power to the HVAC system before working on control wiring.

Steps:

  • 1. Verify settings: Check the humidity setpoint on the Carrier thermostat or humidifier control. Ensure it is not set to OFF or 0%.
  • 2. Inspect wiring: If an external humidistat is used, verify correct wiring between the humidistat and furnace HUM terminals or humidifier control. Look for shorts between wires.
  • 3. Bypass test (for external humidistat): With power off, temporarily jumper the humidistat terminals at the furnace or control. Restore power and see if the humidifier operates. If it does, the humidistat is likely faulty.
  • 4. Replace humidistat or control: Install a new Carrier-compatible humidistat or replace the integrated control if it is not responding correctly.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Humidistat / Humidity Control