F2
Challenge Ambient Temperature Out of Range

Humidifier or dehumidifier shows F2 and stops; may occur in very cold or hot rooms.

Advertisements

Possible Causes

Room temperature below or above design limits, faulty ambient temperature sensor, sensor not positioned correctly in airflow

How to Fix / Troubleshooting

Steps:

  • Check room conditions: Verify the room temperature is within the operating range specified in the manual (commonly 5–35°C). Move the unit if necessary.
  • Inspect ambient sensor: Unplug the unit, remove the front grille, and locate the ambient sensor near the air inlet. Ensure it is not touching hot components or trapped behind insulation.
  • Reseat and test: Reseat the sensor connector on the PCB. If F2 persists in a normal-temperature room, test and replace the ambient temperature sensor (NTC) as needed.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Ambient Temperature Sensor (NTC)
Check Price on Amazon