F2
Challenge
Ambient Temperature Out of Range
Humidifier or dehumidifier shows F2 and stops; may occur in very cold or hot rooms.
Advertisements
Possible Causes
Room temperature below or above design limits, faulty ambient temperature sensor, sensor not positioned correctly in airflow
How to Fix / Troubleshooting
Steps:
- Check room conditions: Verify the room temperature is within the operating range specified in the manual (commonly 5–35°C). Move the unit if necessary.
- Inspect ambient sensor: Unplug the unit, remove the front grille, and locate the ambient sensor near the air inlet. Ensure it is not touching hot components or trapped behind insulation.
- Reseat and test: Reseat the sensor connector on the PCB. If F2 persists in a normal-temperature room, test and replace the ambient temperature sensor (NTC) as needed.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Ambient Temperature Sensor (NTC)
Check Price on Amazon