EC
Comfee
Refrigerant System Error / Low Refrigerant or Sensor Fault
Dehumidifier shows EC and stops cooling; fan may still run.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Low refrigerant charge due to leak, Blocked capillary tube or restriction, Faulty evaporator or condenser temperature sensor, Main PCB misinterpreting pressure/temperature relationship
How to Fix / Troubleshooting
Safety: Unplug the unit. Do not attempt to open the sealed refrigeration system yourself.
- Clean coils and filter: Ensure both evaporator and condenser coils are clean and the air filter is washed and dried. Poor airflow can mimic refrigerant issues.
- Check for icing: After running briefly, inspect the evaporator coil. Heavy ice buildup or only partial frosting can indicate low charge or restriction.
- Sensor inspection: Verify that the coil temperature sensors are firmly attached and their wiring is intact. Replace any suspect coil temperature sensors.
- Professional diagnosis: If EC persists, a licensed technician should check system pressures, locate leaks, and recharge or repair the sealed system as needed.
Advertisements
Repair Difficulty
Professional Required
5/5