Possible Causes

Burned-out fan motor, Obstructed fan blades, Disconnected fan wiring, Failed fan driver circuit on control board

How to Fix / Troubleshooting

Safety first: Unplug the humidifier before opening the housing.

  • 1. Listen for fan:
    • Power on the unit and listen closely; silence from the fan area suggests a non-running fan.
  • 2. Inspect fan:
    • Remove the cover to access the fan.
    • Check for obstructions or broken blades.
  • 3. Spin test:
    • Spin the fan by hand; if stiff or seized, the motor is likely failed.
  • 4. Check wiring:
    • Ensure the fan connector is firmly attached to the control PCB.
  • 5. Replace fan motor:
    • If the motor is seized or open-circuit, replace it with a compatible Crane fan motor assembly.