Crane
Humidity Sensing / Control Fault
Crane humidifier with built-in humidistat runs continuously and does not shut off at the set humidity.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Humidity sensor out of calibration, Sensor blocked by internal moisture, Sensor wiring issue, Control board not responding to sensor input
How to Fix / Troubleshooting
Safety first: Unplug the unit before accessing the sensor.
- 1. Verify with external hygrometer:
- Compare room humidity with a separate hygrometer to confirm the built-in reading is inaccurate.
- 2. Clean sensor area:
- Brush dust from the sensor grille.
- Ensure the sensor is not directly in the mist path.
- 3. Dry condensation:
- If the sensor area is damp, allow the unit to dry completely.
- 4. Replace sensor:
- If readings remain inaccurate, replace the humidity sensor module.
- 5. Control board check:
- If a new sensor does not restore proper cycling, the control PCB may be defective.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Humidity Sensor Module
Check Price on Amazon
We may earn a commission from links on this page.