E2
Crane
Evaporator Temperature Sensor Fault (Dehumidifier)
Crane dehumidifier shows E2 and shuts down shortly after starting.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed evaporator thermistor, Sensor dislodged from coil, Broken sensor wiring, Corroded connector at control board
How to Fix / Troubleshooting
Safety first: Unplug the unit before removing panels.
- 1. Access evaporator sensor:
- Remove the front or rear cover to expose the evaporator coil.
- Locate the small sensor clipped to the coil fins.
- 2. Verify placement:
- Ensure the sensor is firmly clipped to the coil and making good contact.
- 3. Inspect wiring:
- Check the sensor cable for cuts or pinches.
- Confirm the connector is secure on the control PCB.
- 4. Replace sensor:
- If E2 remains, replace the evaporator temperature sensor with the correct Crane part.
- 5. Test operation:
- Reassemble and run the unit; if E2 still appears, the control board sensor circuit may be defective.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Evaporator Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements