E8
Crane High Temperature / Overheat Protection (Dehumidifier)

Crane dehumidifier displays E8 and stops dehumidifying.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked air filter or intake grille, Failed fan motor causing poor airflow, Dirty condenser coil, Faulty temperature sensor on evaporator or condenser

How to Fix / Troubleshooting

Safety first: Unplug the dehumidifier and allow it to cool for at least 20 minutes before servicing.

  • 1. Clean air filter:
    • Remove the front or rear air filter according to the manual.
    • Vacuum or wash with mild soap and water; dry completely before reinstalling.
  • 2. Inspect airflow path:
    • Check intake and exhaust grilles for dust buildup or obstructions.
    • Vacuum grilles and surrounding areas.
  • 3. Check fan operation:
    • With the unit reassembled, power on and listen for the fan.
    • If the fan does not run or is very weak, the fan motor or capacitor may be failing.
  • 4. Clean condenser coil:
    • Unplug and remove the outer cover to access the metal condenser coil.
    • Use a soft brush and vacuum to remove dust; avoid bending fins.
  • 5. Sensor inspection:
    • Locate the temperature sensor clipped to the coil.
    • Ensure it is firmly attached and the wiring is intact.
  • 6. Test:
    • Reassemble and run the unit in a cool, ventilated room.
    • If E8 returns quickly, the temperature sensor or control board may be defective and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator Temperature Sensor
Check Price on Amazon