F1
Danby Keypad / Control Panel Fault

Dehumidifier shows F1 and controls are unresponsive

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck or shorted keypad buttons, Moisture intrusion into control panel, Damaged touchpad membrane, Faulty display/control PCB

How to Fix / Troubleshooting

Safety first: Unplug the unit before working on the control panel.

  • Step 1 – Dry the panel: If the panel was exposed to water or heavy condensation, unplug and allow it to dry for several hours. Do not use the unit until fully dry.
  • Step 2 – Check for stuck buttons: Gently press each button several times to free any that may be stuck. Look for physical damage or cracks.
  • Step 3 – Remove and inspect panel: Take off the control panel cover to inspect the keypad membrane and PCB. Look for corrosion, burnt spots, or broken traces.
  • Step 4 – Replace control panel: If damage is visible or F1 persists, replace the control panel assembly or display PCB with a Danby-compatible part.

When to call a technician: If you are not comfortable disassembling the control panel, or if a new panel does not resolve F1, seek professional service.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Control Panel / Display PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements