F2
De'Longhi
Keypad / Control Panel Error
De'Longhi dehumidifier shows F2 and does not respond to humidity setpoint changes.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck or shorted keypad button, Moisture ingress into control panel, Damaged control panel ribbon cable, Faulty display/control PCB
How to Fix / Troubleshooting
Safety first: Unplug the unit before removing the control panel.
Step-by-step:
- 1. Inspect buttons: Check if any buttons feel stuck or do not click properly. Wipe the panel with a dry cloth.
- 2. Dry out moisture: If the panel has been exposed to condensation or spills, leave the unit unplugged in a warm, dry room for 24 hours to allow moisture to evaporate.
- 3. Check ribbon cable: Remove the top/front cover to access the display board. Reseat the flat ribbon cable connecting it to the main PCB.
- 4. Test again: Reassemble and power on. If F2 persists and buttons still do not respond correctly, the control panel PCB is likely faulty.
- 5. Replace control panel: Order the correct De'Longhi control panel/display board assembly and swap it, transferring any mounting hardware.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Control Panel / Display PCB
Check Price on Amazon
We may earn a commission from links on this page.