Devola
Fan Not Running / Airflow Failure
Devola dehumidifier powers on but fan does not run; compressor may start briefly then stop.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed fan motor, seized fan bearings, faulty fan capacitor (AC motor), broken fan wiring, blocked fan wheel
How to Fix / Troubleshooting
Safety: Unplug before working near the fan.
- Check for obstructions: Remove covers and ensure nothing is blocking the fan.
- Spin test: Try spinning the fan by hand. If stiff, the motor is likely bad and should be replaced.
- Capacitor (if fitted): Locate the fan capacitor and inspect for bulging or leakage. Replace with the same capacitance and voltage rating if suspect.
- Motor replacement: If the motor receives power but does not run, replace the fan motor with the correct Devola part.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Evaporator/Condenser Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.