Devola No Mist Production (Humidifier)

Devola humidifier is on but produces no mist; fan may still run.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Empty or improperly seated tank, scaled ultrasonic transducer, blocked mist outlet, failed transducer driver circuit

How to Fix / Troubleshooting

Safety: Unplug before cleaning or disassembly.

  • Check water level and seating: Ensure the tank is full and correctly positioned so water flows into the base.
  • Descale transducer: Inspect the ultrasonic disc and remove limescale with a vinegar solution as described earlier.
  • Clear mist outlet: Check that the mist nozzle and outlet path are not blocked by mineral deposits or foreign objects.
  • Transducer/PCB replacement: If there is still no mist, the transducer or its driver circuit may have failed. Replace the ultrasonic transducer assembly first; if that fails, replace the main PCB.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ultrasonic Transducer Assembly
Check Price on Amazon

We may earn a commission from links on this page.