H1
Devola
Low Water Level / Tank Empty
Devola humidifier displays H1 and stops producing mist.
Advertisements
Possible Causes
Empty water tank, misaligned tank, faulty water level float or sensor, blocked water inlet to ultrasonic transducer
How to Fix / Troubleshooting
Safety: Unplug the humidifier before refilling or cleaning.
H1 typically indicates that the water tank is empty or not correctly detected.
- Refill tank: Remove the tank, fill it with clean water up to the indicated level, and reinstall it securely.
- Check tank seating: Ensure the tank is properly aligned and fully seated so that the level sensor or float engages.
- Inspect float/sensor: On Devola humidifiers with a float, check that it moves freely and is not stuck with scale. Clean with a soft brush and white vinegar if necessary.
- Clean water inlet: Make sure the valve or opening at the bottom of the tank is not blocked by debris, preventing water from reaching the base.
- Sensor replacement: If H1 persists with a full, correctly seated tank, the water level sensor or reed switch in the base may be faulty and require replacement.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Water Level Float Switch
Check Price on Amazon
We may earn a commission from links on this page.