HI
Devola High Ambient Temperature Indication / Over-Temperature Warning

Devola dehumidifier displays HI and may run continuously.

Advertisements

Possible Causes

Room temperature above specified range, blocked air inlet/outlet, faulty ambient temperature sensor reading too high

How to Fix / Troubleshooting

Safety: Ensure adequate ventilation around the unit.

HI indicates the ambient temperature is very high or the sensor is reading excessively high.

  • Measure room temperature: Use a separate thermometer. If the room is above the Devola maximum (often ~32–35°C), relocate the unit to a cooler area.
  • Improve airflow: Ensure the inlet and outlet grilles are not blocked and that the unit has the recommended clearance.
  • Check and clean filter: A clogged filter can cause internal heat buildup. Wash and dry the filter before reinstalling.
  • Sensor fault: If HI appears in a normal-temperature room, inspect and possibly replace the ambient NTC sensor.
Advertisements

Repair Difficulty

Very Easy 1/5

Required Part

Ambient NTC Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.