E3
Dimplex Humidity Sensor (RH Sensor) Failure

Dehumidifier shows E3 and will not start compressor

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed digital humidity sensor module, Loose or corroded humidity sensor connector, Damaged sensor cable from front panel to main PCB

How to Fix / Troubleshooting

Safety: Unplug the dehumidifier before removing the control panel or front grille.

Steps:

  • Locate the humidity sensor, usually mounted behind the front air inlet grille or integrated into the control panel assembly. It may be a small PCB with a slotted or mesh sensor element.
  • Remove the front grille/control panel as per the service or user manual. Do not pull hard on ribbon cables.
  • Inspect the humidity sensor board and connector for dust, corrosion, or moisture residue. Clean gently with a soft brush and isopropyl alcohol if needed.
  • Reseat the sensor connector on both the sensor board and the main PCB. Check the cable for kinks or breaks.
  • If available, substitute with a known-good Dimplex humidity sensor module or replace with a new OEM part. Ensure correct orientation and secure mounting.
  • Reassemble the panel, restore power, and test. Adjust the humidity setpoint and verify that the display responds and the E3 code is gone.

Tip: Avoid spraying cleaners directly into the control panel area; moisture can damage the RH sensor and cause E3 errors.