LO
Dimplex
Low Ambient Temperature Lockout
Dehumidifier display shows LO and unit does not dehumidify
Advertisements
Possible Causes
Room temperature below minimum operating range, Ambient sensor reading too low due to misplacement or fault
How to Fix / Troubleshooting
Safety: No internal repair is usually required for LO; it is a protective indication.
Steps:
- Check the room temperature. If it is below the minimum specified in the Dimplex manual (often around 5 °C), move the unit to a warmer location.
- Ensure the unit is not placed directly on a cold concrete floor; elevate it slightly to reduce cold conduction.
- If the room is warm but LO still shows, inspect the ambient temperature sensor for correct placement and operation. Replace the sensor if it is reading abnormally low.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Ambient NTC Temperature Sensor
Check Price on Amazon