P1
Dimplex
Defrost Mode Active / Low Coil Temperature Protection
Dehumidifier displays P1 and stops dehumidifying
Advertisements
Possible Causes
Evaporator coil temperature below defrost threshold, Operating in a very cold room, Restricted airflow across evaporator
How to Fix / Troubleshooting
Safety: No internal repair is usually needed for P1; it is a protective mode. Do not bypass safety controls.
Steps:
- Understand that P1 is typically not a fault but an indication that the unit is in defrost mode. The compressor will stop while the fan may continue to run.
- Ensure the room temperature is within the unit's operating range (check the Dimplex manual). If the room is too cold, move the unit to a warmer area.
- Clean the air filter and check for dust buildup on the evaporator coil that could cause excessive icing.
- Allow the unit to complete its defrost cycle. Once the coil warms, P1 should clear automatically and normal operation will resume.
- If P1 remains constantly and the unit never resumes dehumidifying, the evaporator sensor or control board may be misreading coil temperature and should be tested and possibly replaced.
Advertisements
Repair Difficulty
Very Easy
1/5