Dyson Ultrasonic Output Loss Without Code

Dyson humidifier runs but produces no mist at all, fan operates normally, no error code displayed

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Partially failed ultrasonic transducer, Heavy mineral scaling on transducer, Low water level in base reservoir despite full tank, Blocked mist outlet path

How to Fix / Troubleshooting

Safety first: Unplug the humidifier and remove the water tank before cleaning.

  • 1. Verify water transfer: Fill the tank, install it, then remove it again to confirm water has flowed into the base reservoir. If the base is dry, check the tank cap valve and seals for blockage.
  • 2. Descale transducer: Pour a 1:1 white vinegar and warm water solution into the base to cover the transducer area. Let soak 20–30 minutes. Gently wipe the transducer surface with a soft cloth or cotton swab. Rinse thoroughly with clean water and dry.
  • 3. Clear mist outlet: Inspect the mist outlet channel for dust or film. Wipe with a soft cloth dampened with distilled water.
  • 4. Test with distilled water: Refill with distilled water and run the unit on maximum output. If there is still no mist, the transducer is likely weak or failed and should be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ultrasonic Transducer Assembly
Check Price on Amazon