F1
Electrolux Humidity Sensor Calibration / Range Error

Dehumidifier shows F1 and may not respond to humidity setpoint changes.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Drifted or out-of-calibration humidity sensor, Sensor contaminated by dust or chemicals, Loose sensor connector, Faulty main control board ADC circuit

How to Fix / Troubleshooting

Safety first: Unplug the unit before accessing the control panel or sensor.

Steps to correct F1:

  • Clean the sensor area: Remove the front grille and gently clean around the humidity sensor with dry compressed air. Avoid liquids.
  • Reseat connector: Disconnect and reconnect the humidity sensor plug at the main board to ensure a solid connection.
  • Compare humidity reading: Power the unit and compare its displayed humidity to a known-good hygrometer placed nearby. A large discrepancy suggests sensor or board issues.
  • Replace humidity sensor: If readings are unstable or far off, replace the humidity sensor module.
  • Control board replacement: If a new sensor does not resolve F1 or the display still shows unrealistic humidity, replace the main control board.

Warning: Do not attempt to manually recalibrate the sensor unless Electrolux provides a specific procedure for your model.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Humidity Sensor (RH Sensor Module)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements