F2
Electrolux Ambient Temperature Sensor Out-of-Range Error

Dehumidifier displays F2 and may shut down or not start the compressor.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Ambient temperature below or above operating range, Faulty ambient temperature sensor, Sensor wiring shorted to chassis, Control board misreading sensor

How to Fix / Troubleshooting

Safety first: Disconnect power before servicing.

Steps to address F2:

  • Check room temperature: Ensure the unit is operating within the specified temperature range (typically 41–95°F / 5–35°C). Move the unit to a suitable environment if necessary.
  • Inspect sensor location: Make sure the ambient sensor is not touching hot components or placed where it reads incorrectly (e.g., near condenser exhaust).
  • Test sensor: With power off, measure the resistance of the ambient sensor and compare to expected values. Replace if out of range.
  • Inspect wiring: Look for shorts to metal parts or damaged insulation along the sensor wires.
  • Replace control board: If the sensor and wiring are good but F2 persists, the main control board may be defective.

Warning: Do not relocate the sensor away from its designed position; this can cause improper operation.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ambient Temperature Sensor (NTC Thermistor)