LO
Electrolux Low Ambient Temperature Lockout

Dehumidifier display shows LO and unit may not start or runs only fan.

Advertisements

Possible Causes

Room temperature below minimum operating limit, Ambient sensor reading too low due to draft, Faulty ambient temperature sensor reporting low value

How to Fix / Troubleshooting

Safety first: Ensure the unit is unplugged before moving it.

Steps to resolve LO:

  • Check room temperature: Use a thermometer to verify the actual room temperature. If below 41°F (5°C), move the unit to a warmer location.
  • Avoid cold drafts: Do not place the dehumidifier directly on cold concrete or near exterior doors where cold air can affect the sensor.
  • Inspect ambient sensor: If the room is warm but LO still shows, check the ambient sensor for proper placement and damage (see F2 procedure).
  • Replace sensor if needed: Install a new ambient temperature sensor if the old one reads incorrectly.

Note: LO is often a normal protection feature; the compressor will not run in very cold conditions to prevent icing.

Advertisements

Repair Difficulty

Very Easy 1/5

Required Part

Ambient Temperature Sensor (NTC Thermistor)
Check Price on Amazon