Keypad / Membrane Switch Failure
Digital display works but buttons do not respond or only some buttons work.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Worn membrane contacts, Moisture intrusion under keypad overlay, Damaged ribbon cable to control board, Cracked control panel PCB
How to Fix / Troubleshooting
Safety first: Unplug the humidifier before removing the control panel.
- Dry the panel: If there was a spill, allow the panel to dry completely for 24 hours.
- Inspect ribbon cable: Reseat the cable between the keypad and main board.
- Test each button: After reassembly, plug in and test each button. If some remain unresponsive, the keypad is likely defective.
- Replace keypad assembly: Order the correct Essick Air control panel or keypad and swap it, transferring any mounting hardware.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Control Panel / Keypad Assembly
Check Price on Amazon