Possible Causes
Burned-out fan motor, Failed fan capacitor, Obstruction preventing fan from turning, Faulty fan relay on control board
How to Fix / Troubleshooting
Safety: Unplug the unit. Do not run the compressor without a working fan; it can overheat.
Steps to troubleshoot fan:
- Check for obstructions: Remove the grille and ensure nothing is blocking the fan blades.
- Spin test: Try spinning the fan by hand. If it is stiff or seized, the motor is likely bad and must be replaced.
- Inspect capacitor: Locate the fan capacitor (often shared with compressor). If bulging or leaking, replace it.
- Check wiring: Ensure the fan motor wires are securely connected to the control board and capacitor.
- Replace fan motor: If the motor receives power but does not run, replace the fan motor assembly with a GE-compatible part.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Fan Motor / Fan Capacitor