GE Appliances Fan Motor Failure

Dehumidifier fan does not run, but compressor may start and get very hot

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Burned-out fan motor, Failed fan capacitor, Obstruction preventing fan from turning, Faulty fan relay on control board

How to Fix / Troubleshooting

Safety: Unplug the unit. Do not run the compressor without a working fan; it can overheat.

Steps to troubleshoot fan:

  • Check for obstructions: Remove the grille and ensure nothing is blocking the fan blades.
  • Spin test: Try spinning the fan by hand. If it is stiff or seized, the motor is likely bad and must be replaced.
  • Inspect capacitor: Locate the fan capacitor (often shared with compressor). If bulging or leaking, replace it.
  • Check wiring: Ensure the fan motor wires are securely connected to the control board and capacitor.
  • Replace fan motor: If the motor receives power but does not run, replace the fan motor assembly with a GE-compatible part.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Fan Motor / Fan Capacitor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements