Empty or improperly seated water tank, Clogged ultrasonic transducer or wick filter, Failed humidifier fan, Faulty humidifier control circuit

How to Fix / Troubleshooting

Safety: Unplug the unit before servicing the humidifier section.

Steps:

  • Check water tank: Ensure the tank is full, properly seated, and any float or valve is functioning.
  • Clean transducer/wick: For ultrasonic types, gently clean the transducer with a soft cloth and white vinegar. For evaporative types, inspect and replace the wick filter if crusted with mineral deposits.
  • Inspect humidifier fan: Confirm the small fan dedicated to humidifier output runs when humidifier mode is selected.
  • Descale: Use a manufacturer-approved descaling solution to remove mineral buildup from water paths.
  • Control board: If all components are clean and functional but no output, the humidifier control circuit on the board may be faulty and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Humidifier Wick / Ultrasonic Transducer / Humidifier Fan