GE Appliances
Humidifier Output Failure (for GE combo humidifier/dehumidifier units)
Dehumidifier humidifier (if combo) does not produce mist or add moisture
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Empty or improperly seated water tank, Clogged ultrasonic transducer or wick filter, Failed humidifier fan, Faulty humidifier control circuit
How to Fix / Troubleshooting
Safety: Unplug the unit before servicing the humidifier section.
Steps:
- Check water tank: Ensure the tank is full, properly seated, and any float or valve is functioning.
- Clean transducer/wick: For ultrasonic types, gently clean the transducer with a soft cloth and white vinegar. For evaporative types, inspect and replace the wick filter if crusted with mineral deposits.
- Inspect humidifier fan: Confirm the small fan dedicated to humidifier output runs when humidifier mode is selected.
- Descale: Use a manufacturer-approved descaling solution to remove mineral buildup from water paths.
- Control board: If all components are clean and functional but no output, the humidifier control circuit on the board may be faulty and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Humidifier Wick / Ultrasonic Transducer / Humidifier Fan
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements