Possible Causes
Aged or contaminated humidity sensor, Sensor not in proper airflow, Faulty control board ADC circuit
How to Fix / Troubleshooting
Steps to correct humidity reading:
- Verify with external meter: Use a separate hygrometer to compare actual humidity to the dehumidifier's display.
- Clean intake: Ensure the air filter and intake grille are clean so the sensor samples room air properly.
- Check sensor location: Make sure the humidity sensor is not pressed against the coil or cabinet wall; it should be in the airflow path.
- Replace sensor: If readings are consistently off by a large margin, replace the humidity sensor module.
- Control board: If a new sensor does not fix the issue, the main control board may be misreading the sensor and should be replaced.