BU
GE Appliances Bucket Detection Error

Dehumidifier shows BU and stops running, even though bucket appears empty

Advertisements

Possible Causes

Bucket not fully inserted, Broken bucket tab that actuates switch, Misaligned bucket full switch, Failed bucket presence sensor

How to Fix / Troubleshooting

Safety: Unplug the unit before inspecting the bucket area.

Steps to address BU:

  • Remove and reseat bucket: Pull the bucket out completely and reinstall it firmly until it clicks into place.
  • Inspect bucket tabs: Look for plastic tabs or protrusions on the bucket that press the internal switch. If broken, the bucket may need replacement.
  • Check switch alignment: With the bucket removed, locate the bucket switch inside the cavity. Ensure it is not bent or loose.
  • Test switch: Press the switch lever by hand and listen for a click. If it does not click or feels loose, replace the switch.
  • Replace bucket or switch: If the bucket is damaged, replace it with a GE-compatible bucket. If the switch is faulty, replace the bucket presence/bucket full switch.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Bucket Full / Presence Switch
Check Price on Amazon