F0
GE Appliances General Sensor Fault / Sensor Circuit Error

Dehumidifier displays F0 and will not operate normally

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Any thermistor (ambient, evaporator, defrost) open or shorted, Sensor harness unplugged, Corroded sensor connectors, Failed sensor input on main control board

How to Fix / Troubleshooting

Safety: Unplug the unit before inspection.

Steps to address F0:

  • Reset: Unplug for 5–10 minutes, then plug back in. If F0 returns, proceed.
  • Access control board: Remove the control panel cover to expose the main board and sensor connectors.
  • Identify sensors: GE dehumidifiers typically have multiple thermistors: room/ambient, evaporator, and sometimes discharge or defrost. Each connects to the board via 2‑wire plugs.
  • Check all sensor plugs: One by one, ensure each sensor connector is fully seated. Look for corrosion or moisture on pins.
  • Inspect harnesses: Follow each sensor wire to its probe. Check for cuts, pinches, or broken insulation.
  • Test sensors (if possible): Disconnect each thermistor and measure resistance at room temperature. Replace any that read open, shorted, or drastically different from the others.
  • Replace main board: If all sensors test good and F0 persists, the main control board sensor circuit is likely defective and should be replaced.

Tip: Label each sensor connector before unplugging to avoid mixing them up during reassembly.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Thermistor Set / Main Control Board
Check Price on Amazon