F3
GE Appliances
Evaporator Temperature Sensor Error
Dehumidifier shows F3 and may run fan only, no dehumidification
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open or shorted evaporator thermistor, Sensor detached from coil, Harness damage from frost or vibration, Faulty control board sensor circuit
How to Fix / Troubleshooting
Safety: Unplug the unit. Beware of sharp coil fins.
Steps to address F3:
- Inspect coil and sensor: Remove the front panel to expose the evaporator coil. Locate the thermistor clipped to the coil tubing.
- Check attachment: Ensure the sensor is firmly clipped and making good contact with the coil. Reattach if loose.
- Inspect wiring: Look for damage where the sensor wires pass through metal openings. Repair or replace as needed.
- Reconnect at board: Unplug and replug the sensor connector at the main control board.
- Replace sensor: If F3 persists, replace the evaporator thermistor with a GE-compatible part.
- Control board: If a new sensor does not clear F3, replace the main control board.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Evaporator Thermistor
Check Price on Amazon
We may earn a commission from links on this page.