F3
GE Appliances Evaporator Temperature Sensor Error

Dehumidifier shows F3 and may run fan only, no dehumidification

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted evaporator thermistor, Sensor detached from coil, Harness damage from frost or vibration, Faulty control board sensor circuit

How to Fix / Troubleshooting

Safety: Unplug the unit. Beware of sharp coil fins.

Steps to address F3:

  • Inspect coil and sensor: Remove the front panel to expose the evaporator coil. Locate the thermistor clipped to the coil tubing.
  • Check attachment: Ensure the sensor is firmly clipped and making good contact with the coil. Reattach if loose.
  • Inspect wiring: Look for damage where the sensor wires pass through metal openings. Repair or replace as needed.
  • Reconnect at board: Unplug and replug the sensor connector at the main control board.
  • Replace sensor: If F3 persists, replace the evaporator thermistor with a GE-compatible part.
  • Control board: If a new sensor does not clear F3, replace the main control board.