GE Control Panel / Keypad Malfunction

Dehumidifier controls are unresponsive or change settings by themselves.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Moisture in control panel, Stuck or shorted buttons, Faulty user interface board, Electrical noise or static discharge

How to Fix / Troubleshooting

Safety: Unplug before opening the control panel.

Steps to restore control:

  • Dry the panel: If condensation or spills occurred, allow the unit to dry for several hours in a warm, dry room.
  • Clean around buttons: Wipe the panel with a slightly damp cloth, then dry thoroughly. Do not allow liquid to seep into the panel.
  • Inspect inside: Remove the control panel cover and check for corrosion or damage on the user interface board.
  • Reseat connectors: Disconnect and reconnect the ribbon cable to the main board.
  • Replace control panel: If erratic behavior continues, replace the control panel assembly.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Control Panel Assembly
Check Price on Amazon