GE Fan Motor Circuit Failure

Dehumidifier display and buttons work, but fan does not run.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed fan motor, Open fan capacitor (if used), Loose fan motor wiring, Faulty main control board fan relay

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing internal components.

Steps to troubleshoot fan not running:

  • Check for obstructions: Ensure nothing is blocking the fan blades from turning.
  • Access fan motor: Remove the rear or side panel to expose the fan motor and wiring.
  • Inspect wiring: Verify all connectors to the fan motor are secure and not burned.
  • Test motor (advanced): With a multimeter, check for continuity across motor windings. An open circuit indicates a bad motor.
  • Capacitor (if present): Some models use a separate fan capacitor. Replace if bulged or leaking.
  • Control board: If motor and capacitor are good, the main board may not be sending power; replace the main control board if necessary.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements