GE
Display / LED Board Failure
Dehumidifier display is blank or very dim, but the unit may still run.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed display board, Loose ribbon cable, Low voltage from main control board, Moisture damage to control panel
How to Fix / Troubleshooting
Safety: Unplug before removing the control panel.
Steps to restore display:
- Check brightness setting: Some models allow dimming; verify it is not set to minimum.
- Access control panel: Remove screws and gently lift the panel to expose the display board and ribbon cable.
- Reseat cable: Disconnect and reconnect the ribbon cable between the display and main board.
- Inspect for corrosion: Look for moisture or corrosion on the display board. If present, replace the display / user interface board.
- Main board voltage: If you have a meter, verify the main board is supplying the correct low voltage to the display connector. If not, replace the main control board.
Advertisements
Repair Difficulty
Medium