GE
Protection Cycling / Auto Defrost or Overheat Protection
Dehumidifier in continuous mode still shuts off periodically even though humidity is high.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Evaporator coil icing, Compressor overheating, Control board thermal protection, Fan not moving enough air
How to Fix / Troubleshooting
Steps to address cycling in continuous mode:
- Check for ice: Inspect the evaporator coil for frost. If present, follow icing prevention steps.
- Clean filter and coils: Ensure maximum airflow.
- Verify fan speed: Listen for strong airflow. If weak, inspect and replace the fan motor if needed.
- Ventilation: Provide adequate clearance around the unit to prevent overheating.
Advertisements
Repair Difficulty
Medium
3/5