Possible Causes
Failed compressor start relay or PTC, Open compressor winding, Faulty main control board relay, Low ambient temperature lockout
How to Fix / Troubleshooting
Safety: Unplug the unit before accessing the compressor area.
Steps to troubleshoot:
- Confirm conditions: Ensure room temperature is within operating range and humidity is set below current room humidity.
- Listen for compressor: When the unit calls for dehumidification, you should hear a low hum from the compressor. If you only hear the fan, continue.
- Access compressor terminals: Remove the rear or side panel to expose the compressor. Remove the terminal cover.
- Inspect start components: Check the compressor start relay / PTC and overload for burns or cracks. Replace if damaged.
- Test compressor windings (advanced): With a multimeter, check resistance between C-R, C-S, and R-S terminals. Open or shorted readings indicate a bad compressor.
- Control board relay: If compressor and start parts test good, the main board may not be sending power. Inspect and replace the main control board if necessary.