F2
GE
Humidity Sensor Calibration or Circuit Error
Dehumidifier shows F2 and may not maintain set humidity.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Out-of-range humidity sensor, Corroded sensor contacts, Wiring harness damage, Control board analog-to-digital converter fault
How to Fix / Troubleshooting
Safety: Disconnect power before servicing.
Steps to address F2:
- Clean sensor area: Remove the front grille and gently clean dust from the humidity sensor and intake area using compressed air.
- Check wiring: Inspect the humidity sensor harness for damage and ensure the connector is fully seated on the main board.
- Compare humidity reading: Use a separate hygrometer in the same room. If the GE unit's reading is wildly inaccurate, the sensor is likely faulty.
- Replace humidity sensor: Install a new GE humidity sensor / RH sensor module and reconnect it to the board.
- Control board replacement: If a new sensor does not resolve F2, replace the main control board.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Humidity Sensor
Check Price on Amazon
We may earn a commission from links on this page.