F2
Haier
Evaporator Temperature Sensor Error (Alternate Code)
Dehumidifier shows F2 and stops; fan may still run.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed evaporator thermistor, Loose or corroded sensor connector, Sensor wire damaged by coil or ice, Faulty sensor circuit on PCB
How to Fix / Troubleshooting
Safety first: Unplug the unit. Coil fins are sharp; wear gloves.
- Access coil: Remove front panel and filter to expose the evaporator coil.
- Inspect sensor: Locate the thermistor clipped to the coil. Ensure it is firmly attached and not dangling. Check for damaged insulation or broken wires.
- Reseat connector: Follow the sensor wires to the PCB and reseat the connector.
- Test sensor: Use a multimeter to check resistance. Replace the sensor if it is open, shorted, or out of spec.
- PCB diagnosis: If the sensor is good and wiring intact but F2 persists, the main control board may need replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Evaporator Temperature Sensor
Check Price on Amazon