Possible Causes

Defective humidity sensor, Sensor contaminated with dust or moisture, Loose sensor harness, Faulty humidity input on PCB

How to Fix / Troubleshooting

Safety first: Unplug the unit before removing the front grille.

  • Locate humidity sensor: Find the small vented sensor housing near the air intake or on a bracket inside the airflow path.
  • Clean sensor area: Use compressed air or a soft brush to remove dust. Do not spray cleaners directly on the sensor.
  • Check wiring: Ensure the sensor harness is firmly connected at both the sensor and PCB ends.
  • Replace sensor: If F3 persists, replace the humidity sensor assembly with the correct Haier part.
  • PCB replacement: If a new sensor does not resolve F3, the main control board may be defective and require replacement.