H3
Haier Overheat Protection / Heater or Ultrasonic Module Overload

Humidifier shows H3 and shuts down; may feel hot to the touch.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked air outlet, Fan failure (on warm-mist models), Mineral buildup on heating element or ultrasonic transducer, Faulty temperature sensor, Main PCB overheat

How to Fix / Troubleshooting

Safety first: Unplug the humidifier and allow it to cool completely before servicing.

  • Check airflow: Ensure the air outlet and intake are not blocked by objects or dust. Clean grilles with a soft brush.
  • Clean internal components: For ultrasonic models, clean the transducer and water tray with white vinegar to remove mineral deposits. For warm-mist models, descale the heating element per Haier’s instructions.
  • Verify fan operation: If your model has a fan, ensure it runs when the unit is on. A non-running fan can cause overheating.
  • Reset and test: After cleaning and cooling, plug the unit back in and test. If H3 recurs quickly, a temperature sensor or PCB fault is likely and may require professional service.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Heating Element or Ultrasonic Transducer Module